The Beckett GeniSys 12v advanced burner control is a 12 vdc primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors to name a few examples. The GeniSys 12v is used with a suitable cad cell flame sensor to control the oil burner motor, ignitor and optional solenoid valve. It can provide interrupted or intermittent duty ignition and it has a 15 second lockout time.
FEATURES & BENEFITS:
- Programmable valve on delay and motor off delay provides chamber cooling after call for heat.
- Welded relay protection with redundant motor relays
- High ambient temperature rating
- Alarm output enables visual or audio indication of flame failure and lock out condition
- Interrupted Ignition
- Relight function
- Fused protection
ELECTRICAL RATINGS:
INPUTS:
- Voltage: 12 Vdc nominal (11 to 16 Vdc)
- Current: 160 mA plus burner motor, ignitor, and valve loadsOUTPUTS:
- Motor 12Vdc, 20 full load amps (FLA), 100 locked rotor amps (LRA)
- Ignitor: 12Vdc, 5A
- Solenoid Valve: 12 Vdc, 2A
- Lockout Alarm: 12 Vdc, 2AEnvironmental Ratings:
- Storage & operating ambient Temp: -40 degrees F. to +160 degrees F. (-40 degrees C. to +71 degrees C)
- Moisture: 5 to 95% RH, condensing